Maintenance Object Repair Procedures 
Page 10-1577UDS1-BD (UDS1 Interface Circuit Pack) 
10
 2 FAIL The UDS1 interface circuit pack is reporting a Yellow F5 
fault alarm. There is a fault in the User-Network interface 
from the user (PBX) to the network. An out-of-frame 
condition occurs on the remote DS1 endpoint.
If the UDS1 connects to a T1 network facility:
1. Verify that both endpoints of the DS1 link are 
administered using the same signaling mode, 
framing mode, and line coding.
2. Contact T1 Network Service to diagnose the remote 
DS1 endpoint.
3. Check the physical connectivity of the DS1 Interface 
circuit packs and cable.
4. Replace the local UDS1 Interface circuit pack and 
repeat the test. 
5. If the test still fails, then escalate the problem. 
If the UDS1 connects to a line-side terminating device 
such as a PRI terminal adapter:
1. Verify that the switch DS1 and the line-side 
terminating device are administered using the same 
signaling mode, framing mode, and line coding.
2. Investigate the maintenance status of the line-side 
terminating device. Refer to the ’Line-Side 
Terminating Device Operating Manual’ for 
information.
3. Contact the vendor of the line-side terminating 
device to diagnose the equipment.
4. Check the physical connection of the UDS1 
Interface circuit pack to the terminating device. 
Check premise distribution system (or intra-premise 
wiring) for physical connection failures.
5. Replace the local UDS1 Interface circuit pack and 
repeat the test. 
6. If the test still fails, then escalate the problem.
Table 10-463. TEST #141 Yellow Alarm Inquiry Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation