Maintenance Object Repair Procedures 
Page 10-1571UDS1-BD (UDS1 Interface Circuit Pack) 
10
1 FAIL The UDS1 interface circuit pack detected a loss of 
multiframe alarm (LMA). An out of frame condition 
occurred on the UDS1 interface circuit pack. The UDS1 
interface circuit pack will transmit a remote multiframe 
alarm (RMA) to the remote UDS1 endpoint until the LMA 
is retired.
If the UDS1 connects to a T1 network facility or to 
another switch, do the following:
1. Verify that both endpoints of the DS1 link are 
administered using the same signaling mode, 
framing mode, and line coding.
2. Contact T1 Network Service or a technician at the 
far-end switch to diagnose the remote DS1 
endpoint.
3. Check the physical connectivity of the UDS1 packs 
and of the cable.
4. Replace the local UDS1 interface circuit pack, and 
repeat the test.
If the UDS1 connects to a line-side terminating device 
(for example, a PRI terminal adapter), do the following.
1. Verify that the switch DS1 and the line-side 
terminating device are administered using the same 
signaling mode, framing mode, and line coding.
2. Investigate the maintenance status of the line-side 
terminating device. Refer to the ’Line-Side 
Terminating Device Operating Manual’ for 
information.
3. Contact the vendor of the line-side terminating 
device to diagnose the equipment.
4. Check the physical connection of the UDS1 
interface circuit pack to the terminating device, and 
check the premise distribution system (or the 
intra-premise wiring) for physical connection 
failures.
5. Replace the local UDS1 interface circuit pack and 
repeat the test.
Table 10-462. TEST #140 Red Alarm Inquiry Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page