Maintenance Object Repair Procedures 
Page 10-1569UDS1-BD (UDS1 Interface Circuit Pack) 
10
2000 ABORT Response to the test was not received within the 
allowable time period. This may be due to hyperactivity. 
Error type 1538 in the error log indicates hyperactivity. 
The hyperactive circuit pack is out of service and one or 
more of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as test 138 and test 139) 
are aborting with error code 2000.
2. The tests run on the ports of this circuit pack are 
returning a no board result.
3. A ’busyout’ or a ’release’ command has no affect on 
the test results.
4. A ’list config’ command shows that the circuit pack 
and the ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is 
isolated from the system, and all of the trunks for 
this circuit pack are placed into the out of service 
state. The system will try to restore the circuit pack 
within 15 minutes. When no faults are detected for 
15 minutes, the UDS1 interface circuit pack is 
restored to normal operation. All of the trunks for 
the UDS1 interface circuit pack are then returned 
to the in service state. Hyperactivity is often 
caused by the associated facility. In such a case, 
faults (such as slips, misframes, or blue alarms) 
would be entered in the error log. In addition, 
many hardware errors would be logged against 
the associated trunk circuits. If the facility is OK 
and the error occurs again after 15 minutes, 
replace the circuit pack.
Table 10-462. TEST #140 Red Alarm Inquiry Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation