Maintenance Object Repair Procedures 
Page 10-1550UDS1-BD (UDS1 Interface Circuit Pack) 
10
When the test is complete, the maintenance software sends a stop loop around 
message to the UDS1 Interface circuit pack to put the circuit pack back into the 
normal operation mode. All trunks or ports of the UDS1 Interface circuit pack are 
restored to the in-service state after the release board command is entered.
Table 10-459. TEST #135 Internal Loop Around Test 
Error 
Code
Test 
Result Description/ Recommendation
2012 ABORT Internal System Error
1. Retry the reset board command at 1-minute 
intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The 
system may be under heavy traffic conditions or it may 
have time slots out-of-service due to TDM-BUS errors. 
Refer to TDM-BUS Maintenance documentation to 
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not 
handling heavy traffic, repeat test at 1-minute 
intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the 
test. The system may be oversized for the number of 
Tone Detectors present or some Tone Detectors may be 
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, 
refer to TTR-LEV (TTR Level) Maintenance 
documentation. 
2. Look for TONE-PT errors in the Error Log. If present, 
refer to TONE-PT (Tone Generator) Maintenance 
documentation.
3. If neither condition exists, retry the reset board 
command at 1-minute intervals a maximum of 5 
times. 
4. If the test continues to abort, escalate the problem.
Continued on next page