User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1541UDS1-BD (UDS1 Interface Circuit Pack) 
10
x. For later releases of G3V4 and beyond, only error 3585 will show that this 
board is receiving misframes and the AUX data shows the last misframe 
count that was reported.
y. The UDS1 Interface circuit pack has detected a transient hardware logic 
error (for example, program logic inconsistency). This error will disappear 
when no faults are detected for 100 minutes. The value in Aux Data field 
indicates the type of hardware problem.
z. Bad Translation RAM Location Found Error. This error is not 
service-affecting. No action is required. A Bad Translation RAM is 
detected, but the call continues by using another translation location.
aa. LAN Receive Parity Error. This error occurs when the circuit pack detects 
an error in a received frame from the Packet Bus. These errors are most 
likely caused by a Packet Bus problem, but may be due to a circuit pack 
fault.
Refer to the PKT-BUS Maintenance documentation to determine if the 
problem is isolated to this circuit pack or if the problem is caused by 
Packet Bus faults.
ab. Error 3900 is used to give status information on a CPE Loopback Jack 
Test. The value in the Aux Data field indicates the status of the loopback 
test.
ac. Error 3901 is used to give status information on a Far CSU Loopback Test. 
The value in the Aux Data field indicates the status of the loopback test.
ad. Error 3902 is used to give status information on a One-Way Span Test. The 
value in the Aux Data field indicates the status of the span test.
1 
—
Test is currently running.
2 
—
Test failed because loopback could not be activated.
3 
—
Test failed because test pattern could not be detected.
4 
—
Test has been terminated.
1 
—
Test is currently running.
2 
—
Test failed because loopback could not be activated.
3 
—
Test failed because test pattern could not be detected.
4 
—
Test has been terminated.
1 
—
Test is currently running.
2 
—
Test has failed because test could not be activated.
3 
—
Test pattern was not received from the far end.
4 
—
Test has been terminated.