User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1538UDS1-BD (UDS1 Interface Circuit Pack) 
10
busyout board PCSS, reset board PCSS, test board PCSS long, 
release board PCSS. If the error recurs within 10 minutes, then replace 
the circuit pack.
j. CSU Module missing. The 
Near-End CSU Type
 field on the 
add ds1
 form 
has been administered as 
integrated
 but the 120A1 CSU Module is not 
physically connected (or is improperly connected) to the TN464F board 
on the back of the port carrier.
If using the 120A1 CSU Module, plug (or replug) the CSU Module into the 
TN464F circuit pack’s connector on the I/O connector panel on back of 
the carrier. Otherwise, change the 
Near-End CSU Type
 field using the 
change ds1
 form to 
other
.
If this error remains after plugging the CSU Module into the board’s 
connector, there could be a problem with the I/O connector panel.
k. CSU Module not expected. The 120A1 CSU Module is physically 
connected to the TN464F board on the back of the port carrier but the 
Near-End CSU Type
 field on the 
add ds1
 form has not been administered 
as 
integrated
.
If the 120A1 CSU Module is to be used, use the 
change ds1
 command to 
change the 
Near-End CSU Type
 field to 
integrated
. Otherwise, physically 
remove the 120A1 CSU Module from the back of the port carrier.
l. DS1 configuration error. Attempting to use the 120A1 CSU Module with a 
TN464F circuit pack that is configured for 32-channel (2.048 Mbps) 
operation. The CSU Module only works with a DS1 board configured for 
24-channel (1.544 Mbps) operation in the United States of America.
m. DS1 circuit pack suffix incorrect for CSU Module. The 
Near-End CSU Type
field on the 
add ds1
 form has been administered as 
integrated
 but the 
DS1 circuit pack is not a TN464F or later suffix UDS1 board.
If the 120A1 CSU Module is to be used, remove the circuit pack and 
replace it with a TN464F or later suffix board. Otherwise, use the 
change 
ds1 
command to change the 
Near-End CSU Type
 field to 
other
.
n. BLB failure. This error occurs when the DS1 Board Loopback (BLB) 
demand test fails. Repeat the test using the following commands: 
busyout board PCSS
, 
test ds1-loop PCSS ds1/csu-loopback-tests
, 
release board PCSS
. If the BLB test continues to fail, then the TN464F 
circuit pack needs to be replaced.
o. ELB failure. This error occurs when the Integrated CSU (I-CSU) Module 
Equipment Loopback (ELB) test fails. This test is executed by the I-CSU 
during I-CSU power-up/reset (i.e.- TN464F board physically inserted and 
120A1 CSU Module already installed) or when the 120A1 CSU Module is 
plugged on to an already initialized DS1 board. The ELB test is also 
executed as part of the command 
test ds1-loop PCSS 
ds1/csu-loopback-tests
.