User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1513TONE-PT (Tone Generator) 
10
FAIL The Tone Generator could be defective. In a Port 
Network with more than one Tone-Clock circuit pack, the 
system will attempt to move the tone generation function 
to the alternate one.
1. Test the Tone-Clock circuit pack again via the test 
tone-clock PC command
2. If the test fails again, look at the Hardware Error Log 
for Tone Detector circuit pack errors.
3. If there are Tone Detector circuit pack errors, refer to 
Tone Detector Maintenance documentation 
(DTMR-PT, GPTD-PT, CLAS-PT, ETR-PT) to resolve 
these errors first.
4. If there are no Tone Detector circuit pack errors, 
then the Tone-Clock circuit pack should be 
replaced. See ‘‘
How to Replace a Tone-Clock Circuit 
Pack’’ in the TONE-BD section.
PASS The tone generation facility is able to put tones out.
Table 10-452. TEST #90 Tone Generator Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page