User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1508TONE-PT (Tone Generator) 
10
1022 ABORT [G3r V2] Tone detection for the system is administered 
as wide broadband (tone detection mode 5), and the 
Tone Detector used for this test was not a TN420C or 
TN2182 (the only circuit packs with this capability). 
GPTD ports on other types of Tone Detector circuit 
packs are taken out of service since they cannot provide 
the administered function.
1. Change the tone-detection mode administered on 
the system-parameters country-options form (see 
DEFINITY Communications System Generic 3 V2 
Implementation,
 555-230-653,
Or
2. Remove all non-TN420C and non-TN2182 circuit 
packs from the system.
2000 ABORT Response to the test request was not received within the 
allowable time period. System resources required for 
this test are not available.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, follow normal 
escalation procedures.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, follow normal 
escalation procedures.
1 (a) FAIL DTMF generation failed for the active tone generator.
105 (a) FAIL Generation of 440-Hz failed.
109 (a) FAIL Generation of 2225-Hz failed.
110 (b) FAIL Generation of 404-Hz level invalid.
111 (b) FAIL Generation of 1004-Hz low level invalid.
112 (b) FAIL Generation of 1004-Hz high level invalid.
113 (b) FAIL Generation of 2804-Hz level invalid.
Table 10-450. TEST #40 Tone Generator Transmission Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page