User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1490TONE-BD (Tone-Clock Circuit Pack) 
10
Hardware Error Log Entries and Test to Clear 
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set 
options command.
Tone-Clock Circuit Pack Error Log Entries
Error 
Type
Aux 
Data Associated Test Alarm Level
On/Off
 Board Test to Clear Value
0
1
0 Any Any Any test tone-clock PC sh
1(a) 0 Circuit pack 
removed or SAKI 
Sanity Test (#53)
MINOR ON
18(b) 0 busyout tone-clock 
PC
WARNING OFF release tone-clock PC
23(c) 0 None WARNING OFF
125(d) None MINOR ON
126(e) None MINOR ON
257 65535 Control Channel 
Test (#52)
MINOR ON test tone-clock PC r 20
257(f) Any None
513(g) Any None
769(h) 4358 None
1025(i) 4363 NPE Audit Test (50) test tone-clock PC sh
1538(j) Any None MINOR ON
2049(k) 0 Clock Health Inquiry 
Test (#46)
MAJOR ON set tone-clock PC 
override
2305(k) 0 Clock Health Inquiry 
Test (#46)
MAJOR ON set tone-clock PC 
override
2561(l) Any None MAJOR ON
3329(m) 0 None MINOR/ 
WARNING
2
OFF set tone-clock PC
3840(n) Any None
3848(o) 0 Clock Health Inquiry 
Test (#46)
set tone-clock PC 
override
3872(p) 0 None set tone-clock PC 
override
3999 (q) Any None