Maintenance Object Repair Procedures 
Page 10-1467TIE-TRK (Tie Trunk) 
10
The Tie Trunk Dial Test seizes the trunk and outpulses a pause digit.
For a port administered as TGU or a TGE, the Seizure Test internally seizes the 
trunk and outpulses a "pause." The report reports the result of the seizure attempt 
uplink.
Table 10-445. Seizure Tests (#73, #747, #73) 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not 
available. The trunk may be busy with a valid call. Use 
the display trunk xx to determine the trunk 
group/member number of the port. Use the status trunk 
command to determine the service state of the port. If 
the service state indicates that the port is in use, then 
the port is unavailable for certain tests. You must wait 
until the port is idle before retesting. 
1. If the port status is active, but the port is not in use 
(no calls), then check the Error Log for Error Type 
1025 (see Error Log table for description of this error 
and required actions). The port may be locked up. 
The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 
1-minute intervals a maximum of 5 times. 
3. If the test continues to abort, escalate the problem.
Continued on next page