User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1459TIE-TRK (Tie Trunk) 
10
Table 10-443. TEST #33 Loop Around and 
Conference Circuit Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to 
run this test. This could be due to a failure to seize the 
port.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
7 ABORT The conference circuit test was aborted.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
129 ABORT The 404-Hz reflective loop around test aborted. 
Response to the test request was not received within the 
allowable time period.
131 The 1004-Hz reflective loop around test aborted. 
Response to the test request was not received within the 
allowable time period.
133 The 2804-Hz reflective loop around test aborted. 
Response to the test request was not received within the 
allowable time period.
1. Retry the command at 1 minute intervals for a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page