User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1451TIE-TRK (Tie Trunk) 
10
testing configuration allows for the connection of Tie Trunks back-to-back in the 
same switch to verify the operation of Tie Trunk ports. The tests can be 
performed in either the E&M or simplex modes. For details, refer to the "Analog 
Tie Trunk Back-to-Back Testing" section in Chapter 5, ‘‘
Routine Maintenance 
Procedures’’
Hardware Error Log Entries and Test to Clear 
Values
Table 10-441. TIE Trunk Error Log Entries 
Error 
Type Aux Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp s r 1
1 (a)
2
16384
2
None
2
WARNING
2
OFF
2
1 (b)
2
57476
2
None
2
WARNING
2
OFF
2
1 (c)
2
57477
2
None
2
WARNING
2
OFF
2
1 (d)
3
57483
3
None
3
WARNING
3
OFF
3
1 (e)
2
57485
2
None
2
WARNING
2
OFF
2
15 (f) Any Port Audit Update 
(#36); Audit and 
Update (#36) 
18 (g) 0 busyout trunk 
<grp/mbr>
WARNING OFF release trunk 
<grp/mbr>
130 (h)
2
None
2
WARNING
4
ON
4
test trunk 
<grp>/<mbr>
4
257 (i) 57473 None WARNING OFF
257 (j) 57474 None WARNING OFF
257 (k) 57475 None WARNING OFF
513
4
Any
4
EPF M and E Lead 
(#74)
4
MAJ/MIN/ 
WRN
1,4
OFF
4
test port PCSSpp sh r 
3
4
769
4
57481
4
EPF M and E Lead 
(#74)
4
MAJ/MIN/ 
WRN
1,4
ON
4
test port PCSSpp sh r 
3
4
1025 (l) Any
2
57392
5
None MAJ/MIN/ 
WRN
1,2
MINOR
5
OFF
Continued on next page