Page 10-1439TIE-DS1 (DS1 Tie Trunk) 
10
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 
Interface circuit pack to ensure that the trunk’s translation is correct. Translation 
updates include the following data: trunk type (in/out), dial type, timing 
parameters, and signaling bits enabled. The port audit operation verifies the 
consistency of the current state of the trunk kept by the DS1 Interface circuit 
pack and the switch software.
0NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Check to ensure that the board translations are 
correct. Use the list config command, and resolve 
any problems that are found.
2. If the board was found to be correctly inserted in 
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should 
re-establish the linkage between the internal ID and 
the port. If this is not the case, check to see that 
there is a valid board inserted.
Table 10-439. TEST #36 Audit and Update Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-438. TEST #7 Conference Circuit Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page