User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1434TIE-DS1 (DS1 Tie Trunk) 
10
Table 10-438. TEST #7 Conference Circuit Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test were not 
available. The port may be busy with a valid call. Use 
the display port UUCSSpp command to determine the 
trunk group/member number of the port. Use the status 
trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, 
then the port is unavailable for certain tests. You must 
wait until the port is idle before retesting.
1. If the port status is active but the port is not in use 
(no calls), check the error log for error type 1025 
(see the error log table for a description of this error 
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1 
minute intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The 
system may be under heavy traffic conditions, or it may 
have time slots out of service due to TDM-BUS errors. 
The status health command can be used to determine 
if the system is experiencing heavy traffic. Refer to the 
TDM-BUS (TDM bus) Maintenance Documentation to 
diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not 
handling heavy traffic and the port status is idle, 
retry the command at 1 minute intervals for a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page