Page 10-1405TDM-BUS (TDM Bus) 
10
TDM Bus Clock PPM Inquiry Test (#150)
This test evaluates the quality of the synchronization source for the Tone-Clock 
circuit pack.
ANY
(cont’d.)
FAIL 3. If there are no SYNC or DS1-BD errors and
a. this error was logged against the Tone-Clock circuit pack that was 
the current system synchronization reference at the time (use the 
command status synchronization to determine this), replace this 
Tone-Clock circuit pack.
NOTE:
Disruption may occur when executing the following procedures.
b. the Tone-Clock circuit pack you are testing is in Active mode but 
does not contain the current system synchronization reference, 
switch the synchronization reference to the Tone-Clock circuit pack 
under test via the set synchronization PC command. Retry the 
command. If the error is still present, replace this Tone-Clock circuit 
pack. 
c. the Tone-Clock circuit pack under test is in Standby mode, make it 
active via the set tone-clock PC command and switch the 
synchronization reference to it. Reissue the command. If the error is 
still present, replace this Tone-Clock circuit pack.
PASS The Tone-Clock circuit pack does not detect any timing slips. This indicates 
that the external synchronization timing source is valid or that the system 
synchronization reference is a Tone-Clock circuit pack. The status 
synchronization command should be used to verify that the desired 
synchronization reference is providing timing for the system.