Maintenance Object Repair Procedures 
Page 10-1385TAPE-DAT (Tape Consistency) 
10
64 FAIL The update files are different in both SPEs. The update file on the standby 
SPE is most current.
1. If you are on site with the switch, interchange the Active SPE tape with 
the Standby SPE tape. If you are not on site with the switch, issue the 
reset system interchange command. This action causes the Standby 
SPE to become the Active SPE. Refer to the "Reset Commands" section 
in Chapter 8 for information on the side effects of a processor 
interchange.
2. Have INADS issue the copy update-file command. If the update file 
copy passes, proceed to Step 3.
3. Reissue the test tape long command to resolve the alarms.
65 FAIL The update files and translations are different in both SPEs. The Standby 
SPE has the most current update file, and the Active SPE has the most 
current translations.
66 FAIL The update files and translations are different in both SPEs. The Standby 
SPE has the most current update file and translations.
1. Issue the save translations command to save translations on both 
SPEs.
2. Follow the procedures for Error Code #64.
68 FAIL The update files and load vintages are different in both SPEs. The Standby 
SPE has the most current update file.
69 FAIL The update files, load vintages, and translations are different in both SPEs. 
The Standby SPE has the most current update file, and the Active SPE has 
the most current translations.
70 FAIL The update files, load vintages, and translations are different in both SPEs. 
The Standby SPE has the most current update file and translations.
1. Follow the procedures for Error Code #4 to get the correct load 
vintage. After running the test tape long command, check for Error 
Code #32 or #64. Follow the recovery procedure under the applicable 
error code.
72 FAIL The update files and announcements are different in both SPEs. The 
Standby SPE has the most current update file and the Active SPE has the 
most current announcements.
1. Issue the save announcements command to save announcements on 
both SPEs.
2. Follow the procedures for Error Code #64.
Table 10-419. TEST #421 Tape Data Consistency Check Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page