User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1384TAPE-DAT (Tape Consistency) 
10
44 FAIL The update files, load vintages, and announcements are different in both 
SPEs. The Active SPE has the most current update file and 
announcements.
45 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current update file, 
translations, and announcements.
46 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current update file and 
announcements, and the Standby SPE has the most current translations.
1. Follow the procedures for Error Code 4 to get the correct load vintage. 
Be sure to save announcements. After running the test tape long 
command, check for Error Code #32 or #64. Follow the recovery 
procedure under the applicable error code.
48 FAIL The update files and announcements are different in both SPEs. The Active 
SPE has the most current update file, and the Standby SPE has the most 
current announcements.
1. Follow the procedures for Error Code 40.
49 FAIL The update files, translations, and announcements are different in both 
SPEs. The Active SPE has the most current update file and translations, 
and the Standby SPE has the most current announcements.
50 FAIL The update files, translations, and announcements are different in both 
SPEs. The Active SPE has the most current update file, and the Standby 
SPE has the most current translations and announcements.
1. Follow the procedures for Error Code #41.
52 FAIL The update files, load vintages, and announcements are different in both 
SPEs. The Active SPE has the most current update file, and the Standby 
SPE has the most current announcements.
53 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current update file, and 
translations, and the Standby SPE has the most current announcements.
54 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current update file and 
the Standby SPE has the most current translations and announcements.
1. Follow the procedures for Error Code 4 to get the correct load vintage. 
After running the test tape long command, check for Error Code #32 
or #64. Follow the recovery procedure under the applicable error code.
Table 10-419. TEST #421 Tape Data Consistency Check Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page