User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1379TAPE-DAT (Tape Consistency) 
10
Table 10-419. TEST #421 Tape Data Consistency Check Test 
Error 
Code
Test 
Result Description/ Recommendation
0 ABORT The test timed out without completing. This error can occur when the 
system is heavily loaded and the test is not allocated sufficient time to run.
1. Rerun the test when the system is less busy and is not running standby 
maintenance.
1029 
1030 
2011 
2012 
2013 
2014 
2015 
2016 
2017 
2018 
2019 
2020 
2021 
2022 
2023 
2024 
2025 
2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance documentation for a 
description of these error codes.
9005 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35498 ABORT Difficulty was encountered trying to send information between the SPEs.
35512 ABORT The Standby SPE cannot be put into maintenance mode.
1. Resolve all DUPINT (Duplication Interface Circuit Pack), SHDW-LNK 
(Memory Shadowing Link), SHDW-CIR (Common Shadow Circuit), and 
STBY-SPE (Standby SPE) alarms. 
2. Retry the command. 
35514 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35534 ABORT Could not allocate the tape drive (could be active or standby) because 
another tape operation was in progress.
1. Wait 10 minutes, and retry the command.
Continued on next page