User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-13busyout journal-printer 
8
Output
For the following output example, assume that the command that was entered is 
"busyout data-module 300."
Feature Interactions
None.
busyout journal-printer
This command will busyout a maintenance object associated with the system 
technician specified pms-log or wakeup-log.
Synopsis
busyout journal-printer [ pms-log | wakeup-log ]
Port The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being busied out, or the number of the data 
channel.
Maintenance Name The type of maintenance object that is being busied out.
Alt. Name The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xxx 
when the object is a private CO line, where xxx is the private CO 
line group number.
Result An indicator as to whether the object was successfully busied 
out.
Error Code A numerical description of why the command failed.
 busyout data-module 300 SPE A
 COMMAND RESULTS
 Port Maintenance Name Alt. Name Result Error Code
 01C1103 DIG-LINE 300 PASS
 Command successfully completed