User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1365TAPE (Tape Unit) [G3iV1.1-286] 
10
9026 Hardware error detected. 1. Do the steps below following the 
directions in the ‘‘
Tape Maintenance 
and Repair Procedures’’ section.
2. Issue the test tape long 
commnd.dispatch with tape unit.
3. If the test fails, make sure tape is fully 
inserted.
4. If the test continues to fail, clean the 
tape head. 
Use original tape
 and 
retest.
5. If the test still fails, swap tape unit, 
use 
original tape
 and retest.
NOTE:
It is very important that hardware 
problems are resolved 
before
 using 
backup tape.
6. If fails again, swap tape and restest.
7. If the problem still exists, escalate the 
problem.
9027 The test failed because the 
software could not access 
the tape hardware.
9030 Internal system error. 1. Follow the steps provided in the ‘‘
Tape 
Maintenance and Repair Procedures’’ 
section.
2. If problem still exists then escalate.
9032 Inability to read a 
significant portion of the 
scratch area on the tape.
1. Follow the steps provided in the ‘‘
Tape 
Maintenance and Repair Procedures’’ 
section.
2. If problem still exists then escalate.
Table 10-415. Table A: Tape Unit Aux Data Table — Continued
Aux Data/ 
Error Codes Explanation Strategy