Maintenance Object Repair Procedures 
Page 10-1351TAPE (Tape Unit) [G3iV1.1-286] 
10
NOTE:
In a High or Critical Reliability system, the following repair procedure 
assumes that no major alarms exist on the PROCR (Processor), 
MEM-BD (Memory), or DUPINT (Duplication Interface) circuit packs 
or on the STBY-SPE (Standby SPE) MO. If any of these alarms exists, 
resolve them before trying to resolve this alarm.
Both Active and Standby SPE Tapes alarmed 
This situation arises whenever translations cannot be loaded on either 
SPE. If the system was powered up, both tapes were alarmed at almost 
the same time as a result of this error. It is very possible that no 
SPE-Interchange occurred. However, if the system was restarted as a 
result of a reset system [3 | 4 | 5] command, and when an alarm was 
raised against the Active SPE as a result of Error Type #3329, a Level 3 
SPE-Interchange automatically occurred, and the "new" Active SPE 
attempted to load translations. When this SPE failed to load translations, 
its tape was alarmed as well.
Error Type #3329 - Repair Procedure #1 (High or Critical Reliability 
System): 
1.Issue the status system command to determine which SPE
(A or B), is the Active SPE. It is labeled as "active."
2.Use "Error Type #3329—Repair Procedure (Standard System)" to ensure 
that the tape and tape unit in the Active SPE are functioning 
properly and to read in translations.
3.Log into the Manager I terminal again and issue the display alarms 
command to see if any alarms were raised against the Active SPE 
tape.
a. If a major alarm against the Active SPE tape now exists, 
escalate the problem.
b. If minor alarms against the Active SPE tape now exist, 
resolve those alarms before continuing with Step #5.
c. If no alarm exists against the Active SPE tape, continue with 
Step #4.
4.Replace the tape in the Standby SPE. If a new tape is used, translations 
must have been successfully saved in order to clear Error Type 
#3329.
5.Issue the refresh spe-standby command. It may be necessary to issue 
this command multiple times. However, if you have issued the 
refresh spe-standby command five times, and if the Standby SPE 
is still not labeled "Standby" on the Status System Form, escalate 
the problem.