Maintenance Object Repair Procedures 
Page 10-1333SYNC (Synchronization) 
10
2.Test the active Tone-Clock circuit pack in the master port network via the 
test tone/clock PC long command. Check the Error Log for 
TDM-CLK errors and verify that TDM Bus Clock Test #148 passes 
successfully. If Test #148 fails with an Error Code 2 through 32, 
refer to the TDM-CLK (TDM Bus Clock) Maintenance 
documentation to resolve the problem. If not, continue with the 
following steps.
3.High or Critical Reliability system: Switch Tone-Clock circuit packs on 
the master port network via the set tone/clock PC command.
Standard system: Replace the primary and secondary (if 
administered) DS1 Interface circuit packs.
4.Check for an error logged against the primary or secondary DS1 board. 
If there is an error, follow the DS1 section to resolve the errors. If 
there is not, enter enable sync, and wait for two to five minutes for 
the primary sync source to come on-line.
In Release 5si + memory: This error indicates that some reference 
switches have occurred. If there is not a major SYNC alarm, then 
investigate other SYNC errors. If there is an active major SYNC 
alarm, and if this is not a Stratum 3 system, then follow the steps 
above.
f. This error indicates that the Expansion Interface Link is experiencing 
timing slips. The two port networks are not synchronized. This error 
increases the bit error rates for data transmission between port networks. 
Verify that all the TDM/LAN Bus cables on the backplane are AT&T Parts 
number AT&T SK00199-001 rather than flat ribbon cables. Also, check 
that the bus terminators are the ZAHF V1 TDM/LAN Bus Terminator type. 
Refer to note (i) for error resolution steps.
This error is cleared by a leaky bucket strategy and takes one hour to 
clear (leak away) the error counter once it is alarmed. Therefore, it may 
take up to one hour to clear the alarm after the problem is cleared.
g. This error indicates that the slave Tone-Clock circuit pack is experiencing 
loss of signal. Refer to note (i) for error resolution steps.
h. The following steps should be executed to resolve error 2049 and 2305:
1.Check for timing loops, and resolve any loops that exist.
2.Check the Error Log for any active as well as resolved Expansion 
Interface circuit pack errors and refer to EXP-INTF (Expansion 
Interface Circuit Pack) Maintenance documentation to resolve any 
errors found.
3.High or Critical Reliability system: 
■ Switch Tone-Clock circuit packs in the slave port network via 
the set tone/clock PC system technician command. The 
error count for this particular error should start decrementing 
once the problem is solved—if the count does not decrease 
in 15 minutes the problem still persists.