Maintenance Object Repair Procedures 
Page 10-1317SW-CTL (Switch Control) 
10
Table 10-397. TEST #93 Switch Control Reset Test 
Error 
Code
Test 
Result Description/ Recommendation
2012 ABORT Internal system error
2013 
2100 
none
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT Refer to Standby SPE for a description of these error codes.
2000 or 
None
FAIL The Switch Control could not be successfully reset. If this is a standard 
system, the customer probably cannot make or receive calls.
1. This failure could be due to either a Network Control circuit pack 
failure or the loss of system timing signals. If the Switch Control is 
alarmed, then suspect a Network Control circuit pack failure. If the 
Switch Control is not alarmed, investigate the possible loss of system 
timing signals. See “TDM Bus Clock”. If many port circuit pack LEDs 
are lit, suspect a TDM Bus Clock problem. If only the Network Control 
circuit pack LED is lit, suspect the Network Control circuit pack. If the 
Network Control circuit pack is determined to be at fault, proceed to 
Step 2.
2. If the system can process calls, replace the Netcon board.
3. If calls cannot be made, replace the Netcon board.
4. The procedure for replacing the Netcon circuit pack in a High or 
Critical Reliability system is described in Chapter 6, ‘‘
Reliability 
Systems: A Maintenance Aid’’. The procedure for doing the same in 
systems without High or Critical Reliability is described in Chapter 5, 
‘‘Routine Maintenance Procedures’’.
PASS The Switch Control has initialized correctly. Look at results of the other 
tests to see if it is operating correctly.