Maintenance Object Repair Procedures 
Page 10-1303STRAT-3 (Stratum 3 Clock)] 
10
1 FAIL Either Reference A failed or CI card A failed. This 
condition usually indicates a failure of the DS1 
reference; however, there may also be a failure of the CI 
card to which the reference is connected. System 
Technician dispatched to investigate this problem 
should take a spare CI card in case the CI card caused 
the failure.
If you are NOT ON-SITE, use the following procedure:
1. Look for DS1-BD (DS1 Interface Circuit Pack) errors 
using the display error command. Refer to the 
DS1-BD Maintenance documentation for 
recommended strategy to resolve any DS1-BD 
errors found.
2. If there are no DS1-BD errors OR after resolving all 
DS1-BD errors, issue the test synchronization r 4 
command to determine if the alarm is still present. If 
all repetitions of the tests pass, then the alarm no 
longer exists. Otherwise, system technician should 
be dispatched with a spare CI card to use the 
following instructions on-site.
If you are ON-SITE, use the following procedure:
1. Look for a red LED on CI card A (that is, the left CI 
card). If there is a red LED, then replace the CI card, 
if a spare is available. If no spare CI is available 
on-site, proceed to Step 3. If after replacing the CI 
card, the red LED on the new CI card lights also, 
then proceed to Step 3.
2. If a spare CI card is available, replace the suspect 
CI card. Otherwise, issue the test synchronization 
r 4 command to clear the alarm. If any test 
repetitions fail, follow the procedure for those 
failures.
Table 10-394. TEST #649 Stratum 3 Clock Alarm Query — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page