Page 10-1300STRAT-3 (Stratum 3 Clock)] 
10
Maintenance documentation. Before switching back to the new 
TN780 Tone-Clock circuit pack, use the test tone-clock PC long 
command to check that the Tone-Clock is receiving a signal from 
the Stratum 3 clock. The notation "PC" denotes a port network 
number and carrier. If all tests pass, switch to the new Tone-Clock 
circuit pack via the set tone-clock PC override command. If Test 
#651 fails, then the original TN780 Tone-Clock should be 
reinserted, and the cable between the Stratum 3 clock and the 
TN780 Tone-Clock circuit pack should be replaced. If Test #651 
continues to fail, then escalate the problem.
c. This error indicates that the Tone/Clock circuit pack in the master port 
network is not a TN780 Tone/Clock circuit pack when a Stratum 3 clock is 
administered. Verify that the Tone/Clock in the master port network is 
TN780.
d. This error indicates that the Stratum 3 clock has either reference A or CI 
card A failed. Please refer to the error code 1 in the test description of the 
Test #649 for the repair procedure.
e. This error indicates that the Stratum 3 clock has one power supply failed. 
Please refer to the error code 2 in the test description of the Test #649 for 
the repair procedure.
f. This error indicates that the Stratum 3 clock has one clock unit failed. 
Please refer to the error code 4 in the test description of the Test #649 for 
the repair procedure.
g. This error indicates that the Stratum 3 clock has either reference B or CI 
card B failed. Please refer to the error code 8 in the test description of the 
Test #649 for the repair procedure.
h. This error indicates that the Stratum 3 clock has all power supplies failed. 
Please refer to the error code 16 in the test description of the Test #649 for 
the repair procedure.
i. This error indicates that the Stratum 3 clock has all clock units failed. 
Please refer to the error code 32 in the test description of the Test #649 for 
the repair procedure.