User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1291STBY-SPE (Standby SPE) 
10
2025
(cont’d.)
ABORT ■ If none of the three red LEDs is on AND if this is the fourth attempt to 
clear the problem (that is, the Standby SPE Processor, Standby SPE 
Memory, and carrier A Duplication Interface circuit packs have already 
been replaced), proceed with Step 10.
■ If none of the three red LEDs is on AND if this is the fifth attempt to clear 
the problem (the Standby SPE Processor, Standby SPE Memory, and 
carrier A Duplication Interface circuit packs have been replaced and 
the test has been repeated once), escalate the problem.
10. Issue the refresh spe-standby command to put the Standby SPE into 
Standby Mode. This command may have to be issued multiple times. If the 
refresh spe-standby command successfully completes five times without 
the Standby SPE becoming labeled "standby" on the status system form, 
wait 20 minutes. This does not include cases where the command 
completes with the terminal message line errors "Refresh not successful; 
use ‘display errors’ to check for STBY-SPE errors" or "Cannot interrupt 
Standby SPE while entering maintenance mode; please try later." Issue the 
refresh spe-standby command once more. If the Standby SPE is not 
labeled "standby" on the status system form after this attempt, use the 
busyout spe-standby and release spe-standby command to put the 
standby into standby mode.
11. Repeat the command.
12. Issue the test spe-standby long command.
Table 10-392. Test Result Error Codes Associated with the Standby SPE
 — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page