User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1287STBY-SPE (Standby SPE) 
10
2024
(cont’d.)
ABORT 10. Issue the display errors command and check to see if Error Type 58 is 
logged against STBY-SPE. If an Error Type 58 is logged OR if none of the 
three error types are logged, the problem is either the Standby SPE 
Processor circuit pack or the Standby SPE Memory circuit pack or the 
carrier A Duplication Interface circuit pack.
■ If the red LED on the Standby SPE Processor circuit pack is on and the 
Standby SPE Processor circuit pack has not been replaced yet, 
replace the Standby SPE Processor circuit pack as described in 
Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and proceed with 
Steps 11, 12, and 13. If the red LED on the Standby SPE Processor 
circuit pack is on, and if the Standby SPE Processor circuit pack has 
been replaced, replace the Standby SPE Memory circuit pack as 
described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and 
proceed with Steps 11, 12, and 13.
■ If the red LED on the Standby SPE Memory circuit pack is on, replace 
the Standby SPE Memory circuit pack as described in Chapter 6, 
‘‘Reliability Systems: A Maintenance Aid’’ and proceed with Steps 11, 
12, and 13.
■ If the red LED on the carrier A Duplication Interface circuit pack is on, 
replace the carrier A Duplication Interface circuit pack as described in 
Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and proceed with 
Steps 11, 12, and 13.
■ If none of the three red LEDs is on AND if this is the first attempt to clear 
the problem, replace the Standby SPE Processor circuit pack as 
described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and 
proceed with Steps 11, 12, and 13.
2024
(cont’d.)
ABORT ■ If none of the three red LEDs is on AND if this is the second attempt to 
clear the problem, replace the Standby SPE Memory circuit pack as 
described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and 
proceed with Steps 11, 12, and 13.
■ If none of the three red LEDs is on AND if this is the third attempt to 
clear the problem, replace the carrier A Duplication Interface circuit 
pack as described in Chapter 6, ‘‘
Reliability Systems: A Maintenance 
Aid’’ and proceed with Steps 11, 12, and 13.
■ If none of the three red LEDs is on AND if this is the fourth attempt to 
clear the problem, replace the carrier B Duplication Interface circuit 
pack as described in Chapter 6, ‘‘
Reliability Systems: A Maintenance 
Aid’’ and proceed with Steps 11, 12, and 13.
■ If none of the three LEDs is on AND if this is the fifth attempt to clear the 
problem, escalate the problem.
Table 10-392. Test Result Error Codes Associated with the Standby SPE
 — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page