User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1284STBY-SPE (Standby SPE) 
10
2020 ABORT The test requires that a maintenance activity request be made to the Standby 
SPE; however, the request cannot be made because the Active SPE was 
restarted within the last five minutes and has not yet initialized the Standby 
SPE. Therefore, the Standby SPE is not available to handle maintenance 
activity requests.
1. Issue the refresh spe-standby command to force the Standby SPE to 
Standby Mode. This command may have to be issued multiple times. If the 
refresh spe-standby command successfully completes five times without 
the Standby SPE becoming labeled "standby" on the status system form, 
wait 20 minutes. This does not include cases where the command 
completes with the terminal message line errors "Refresh not successful; 
use ‘display errors’ to check for STBY-SPE errors" or "Cannot interrupt 
Standby SPE while entering maintenance mode; please try later." Issue the 
refresh spe-standby command once more. 
2. Repeat the test.
3. If the Active SPE was restarted with a Cold 1 or a reboot, issue the test 
spe-standby long command to thoroughly test all Standby SPE 
components.
2021 ABORT An attempt to refresh Standby SPE memory from Active SPE memory 
encountered a problem. In this case, the refresh from Active SPE Memory to 
Standby SPE Memory probably succeeded. However, the following steps 
should be followed just to verify that there are no problems.
1. Check for Active SPE Memory errors and alarms. Refer to MEM-BD 
(Memory circuit pack) Maintenance and follow the prescribed 
maintenance procedures.
2. Issue the refresh spe-standby command. This command may have to be 
issued multiple times. If the refresh spe-standby command successfully 
completes five times without the Standby SPE becoming labeled "standby" 
on the status system form, wait 20 minutes. This does not include cases 
where the command completes with the terminal message line errors 
"Refresh not successful; use ‘display errors’ to check for STBY-SPE errors" 
or "Cannot interrupt Standby SPE while entering maintenance mode; 
please try later." Issue the refresh spe-standby command once more. 
2022 ABORT The Active SPE successfully put the Standby SPE into Maintenance Mode but 
received an incorrect response to a maintenance activity request that it made 
to the Standby SPE OR, once in Maintenance Mode, the Standby SPE sent a 
request to the Active SPE to have the Active SPE conduct a portion of a test in 
the Standby SPE’s behalf, but the Standby SPE received an incorrect response 
to its request. The communication path between the Active SPE and the 
Standby SPE may have failed. Follow the procedures described for Error Code 
2024 in the STBY-SPE section.
Table 10-392. Test Result Error Codes Associated with the Standby SPE
 — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page