Page 10-1280STBY-SPE (Standby SPE) 
10
Table 10-392. Test Result Error Codes Associated with the Standby SPE
Error 
Code
Test 
Result Description/ Recommendation
4 ABORT The Active SPE was unable to disable or enable shadowing from Active SPE 
memory to Standby SPE memory. The communication path between the Active 
SPE and the carrier A Duplication Interface circuit pack may have failed, or the 
carrier A Duplication Interface circuit pack may have failed.
1. Check for Active SPE Maintenance/Tape Processor errors and alarms. 
Refer to PR-MAINT (Maintenance/Tape Processor) Maintenance 
documentation and follow the prescribed procedures.
2. Check for carrier A Duplication Interface circuit pack errors and alarms. 
Refer to DUPINT (Duplication Interface Circuit Pack) Maintenance 
documentation and follow the prescribed procedures.
3. If the B carrier contains the Active SPE, check the Inter-Carrier Cable to 
see if it is loose or disconnected. If so, follow the repair procedures for 
connecting the Inter-Carrier Cable described in Chapter 6, ‘‘
Reliability 
Systems: A Maintenance Aid’’.
4. If all problems found in Steps 1, 2, and 3 have now been repaired, 
proceed with Step 7. If no problems were found in Steps 1, 2, and 3, 
proceed with Step 5.
5. Issue the display errors command and check to see if an Error Type 80 is 
logged against STBY-SPE. If so, the problem is the carrier A Duplication 
Interface circuit pack. Replace the carrier A Duplication Interface circuit 
pack as described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ 
and proceed with Steps 7, 8, and 9.
Continued on next page