Maintenance Object Repair Procedures 
Page 10-1252SPE-SELEC (SPE Select Switch) 
10
Error Log Entries and Test to Clear Values
Notes:
a. The Warning alarm is upgraded to Major if the error is not resolved in six 
hours.
b. Determine the carrier (a or b) by the Port field in the Error or Alarm Log. 
For SPE-SELEC, the Port field is 1A (test duplication interface a) or 1B 
(test duplication interface b).
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Duplication Interface Circuit Pack Status Query 
Test,
 for example, you may also clear errors generated from other tests in the 
testing sequence.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. This error type initially raises a Warning alarm. If this error type persists and alarms are not 
downgraded on this MO due to the values of set options, then, after a period of time, a Major alarm 
is raised.
Table 10-389. SPE Select Switch Error Log Entries
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test duplication-interface 1C 
sh r 1
1 Any SPE Select Query 
Test (#278)
WARNING/ 
MAJOR
2
OFF test duplication-interface 1C 
sh r
257 any SPE Select Query 
Test (#278)
WARNING/ 
MAJOR
2
OFF test duplication-interface 1C 
sh r 2
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
Duplication Interface Circuit Pack Status Query Test 
(#315) (a)
XXND
Duplication Interface Circuit Pack Sanity Circuit Test 
(#273) (a)
XD
Continued on next page