User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1244SHDW-LNK (Memory Shadowing Link) 
10
2048
(cont’d.)
FAIL Refer to Chapter 6 to understand how to correctly replace the 
Duplication-Interface circuit pack.
■ If none of the four red LEDs are on AND if this is the first attempt to 
clear the problem, replace the Standby SPE Processor circuit pack 
as described in Chapter 6 and proceed with Steps 9, 10, and 11.
■ If none of the four red LEDs are on AND if this is the second attempt 
to clear the problem (that is, the Standby SPE Processor circuit 
pack has already been replaced), replace the Standby SPE Memory 
circuit pack as described in Chapter 6 and proceed with Steps 9, 
10, and 11.
■ If none of the four red LEDs are on AND if this is the third attempt to 
clear the problem (that is, the Standby SPE Processor and Standby 
SPE Memory circuit packs have already been replaced), replace 
the Standby SPE Duplication Interface circuit pack as described in 
Chapter 6 and proceed with Steps 9, 10, and 11.
■ If none of the four red LEDs are on AND if this is the fourth attempt 
to clear the problem (that is, the Standby SPE Processor, Standby 
SPE Memory, and Standby SPE Duplication Interface circuit packs 
have already been replaced), replace the Active SPE Duplication 
Interface circuit pack as described in Chapter 6 and proceed with 
Steps 9, 10, and 11.
NOTE:
The Duplication Interface circuit pack must be made to reside in the 
Standby SPE before it can be replaced.
Table 10-388. TEST #318 Shadow Link Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page