User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1243SHDW-LNK (Memory Shadowing Link) 
10
2048
(cont’d.)
FAIL 6. Issue the display errors command and check to see if an Error Type 
82 is logged against STBY-SPE. If so, the problem is the carrier B 
Duplication Interface circuit pack. Replace the carrier B Duplication 
Interface circuit pack as described in Chapter 6 and proceed with 
Steps 9, 10, and 11.
7. Issue the display errors command and check to see if an Error Type 
85 is logged against STBY-SPE. If so, the problem may be the Standby 
SPE Memory circuit pack. Replace the Memory circuit pack as 
described in Chapter 6 and proceed with Steps 9, 10, and 11.
8. Issue the display errors command and check to see if an Error Type 
58 is logged against STBY-SPE. If an Error Type 58 is logged OR if no 
error types are logged against STBY-SPE, the problem is either the 
Standby SPE Processor circuit pack, or the Standby SPE Memory 
circuit pack, or the carrier B Duplication-Interface circuit pack, or the 
carrier A Duplication-Interface circuit pack.
■ If the red LED on the Standby SPE Processor circuit pack is on and 
the Standby SPE Processor circuit pack has not been replaced yet, 
replace the Standby SPE Processor circuit pack as described in 
Chapter 6 and proceed with Steps 9, 10, and 11. If the red LED on 
the Standby SPE Processor circuit pack is on and the Standby SPE 
Processor circuit pack has been replaced, replace the Standby SPE 
Memory circuit pack as described in Chapter 6 and proceed with 
Steps 9, 10, and 11.
■ If the red LED on the Standby SPE Memory circuit pack is on, 
replace the Standby SPE Memory circuit pack as described in 
Chapter 6 and proceed with Steps 9, 10, and 11.
■ If the red LED on the Standby SPE Duplication Interface circuit pack 
is on, replace the Standby SPE Duplication Interface circuit pack as 
described in Chapter 6 and proceed with Steps 9, 10, and 11.
9. If the red LED on the Active SPE Duplication Interface circuit pack is 
on, replace the Active SPE Duplication Interface circuit pack as 
described in Chapter 6 and proceed with Steps 9, 10, and 11
Table 10-388. TEST #318 Shadow Link Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page