Maintenance Object Repair Procedures 
Page 10-1241SHDW-LNK (Memory Shadowing Link) 
10
2047 FAIL The Standby SPE Maintenance/Tape Processor released the Standby SPE 
processor with a request to clear Standby SPE Memory; Standby SPE 
Memory was not successfully cleared.
1. Check for Standby SPE Processor errors and alarms. Refer to PROCR 
(80286 Processor Circuit Pack) Maintenance documentation and follow 
the prescribed procedures.
2. Check for Standby SPE Memory errors and alarms. Refer to MEM-BD 
(Memory) Maintenance documentation and follow the prescribed 
procedures.
3. If all problems found in Steps 1 and 2 have now been repaired, 
proceed with Step 5. If no problems were found in Steps 1 and 2, 
proceed with Step 4.
4. Issue the display errors command and check to see if an Error Type 
58 is logged against STBY-SPE. If an Error Type 58 is logged OR if no 
error types are logged against STBY-SPE, the problem is either the 
Standby SPE Processor circuit pack or the Standby SPE Memory circuit 
pack.
■ If the red LED on the Standby SPE Processor circuit pack is on and 
the Standby SPE Processor circuit pack has not been replaced yet, 
replace the Standby SPE Processor circuit pack as described in 
Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and proceed 
with Steps 5, 6, and 7. If the red LED on the Standby SPE Processor 
circuit pack is on and the Standby SPE Processor circuit pack has 
been replaced, replace the Standby SPE Memory circuit pack as 
described in Chapter 6 and proceed with Steps 5, 6, and 7.
■ If the red LED on the Standby SPE Memory circuit pack is on, 
replace the Standby SPE Memory circuit pack as described in 
Chapter 6 and proceed with Steps 5, 6, and 7.
■ If neither red LED is on AND if this is the first attempt to clear the 
problem, replace the Standby SPE Processor circuit pack as 
described in Chapter 6 and proceed with Steps 5, 6, and 7.
■ If neither red LED is on AND if this is the second attempt to clear the 
problem (that is, the Standby SPE Processor circuit pack has 
already been replaced), replace the Standby SPE Memory circuit 
pack as described in Chapter 6 and proceed with Steps 5, 6, and 7.
■ If neither red LED is on AND if this is the third attempt to clear the 
problem (the Standby SPE Processor and Standby SPE Memory 
circuit packs have been replaced), escalate the problem.
Table 10-388. TEST #318 Shadow Link Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page