User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1231SHDW-CIR (Common Shadow Circuit) 
10
demanded by maintenance software and can be run on both Duplication 
Interface circuit pack A and Duplication Interface circuit pack B. The same 
addresses used in the Common Shadow Circuit Circuit Loop Back Test (#283) 
are used.
Table 10-385. TEST #284 Common Shadow Circuit 
Address Decoder Test 
Error Code
Test 
Result Description/ Recommendation
1029 1030 
2011 2012 
2013 2014 
2015 2016 
2017 2018 
2019 2020 
2021 2022 
2023 2024 
2025 2051
ABORT Refer to the STBY-SPE Maintenance documentation for a description of 
these error codes.
ABORT Internal system error
1022 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Common Shadow Circuit portion of the Duplication Interface circuit 
pack is defective and the Duplication Interface circuit pack must be 
replaced.
1. Follow the "Repair Procedures for High and Critical Reliability" in 
Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and replace the 
Duplication Interface circuit pack.
2. Rerun the test. 
NO 
BOARD
The Duplication Interface circuit pack has failed to handshake with either 
the active Maintenance/Tape Processor (in the case of Duplication 
Interface circuit pack A) or the Duplication Interface circuit pack A (in the 
case of Duplication Interface circuit pack B).
1. Refer to NO BOARD description for the Duplication Interface Circuit 
Pack Status Query Test (#315) in DUPINT Maintenance 
documentation.
PASS Part of the Common Shadow Circuit is operating properly; however, Tests 
#283 and #285 must pass before the Common Shadow Circuit on this 
Duplication Interface circuit pack is considered sane.
Continued on next page