Page 10-1206RING-GEN (Analog Ring Generator) 
10
FAIL
(cont’d.)
PROCEDURE FOR A SINGLE-CARRIER CABINET 
SYSTEM.
This failure indicates that there is no ringing voltage in 
the carrier where the active tone/clock circuit pack 
resides. Other carriers may or may not have ringing 
voltage.
1. If this is a Duplicated Option system, then determine 
the active Tone-Clock circuit pack by issuing a 
status port-network command. Make the Standby 
Tone-Clock circuit pack active via the set 
tone-clock PC command and rerun the test.
a. If the test passes, then the trouble is with the 
"new" Standby Tone-Clock circuit pack. Refer to 
TONE-BD (Tone-Clock Circuit Pack) Maintenance 
documentation for details on replacing the 
Standby Tone-Clock circuit pack. After the circuit 
pack is replaced, make this Tone-Clock active 
again by issuing the set tone-clock PC 
command and rerun the test.
b. If the test fails, then proceed with Step 2.
2. Unseat all analog circuit packs in the cabinet that 
contains the Active Tone/Clock circuit pack and 
rerun the test.
3. If the test passes, then the Analog Ring Generator is 
healthy and one of the analog circuit packs is 
defective. Replace the analog circuit packs one at a 
time, and rerun the test to determine which circuit 
pack is causing the problem. When the defective 
analog circuit pack is found, replace it. Rerun the 
test. If the test still fails, go to Step 4.
4. Replace the WP-91153 power unit for the affected 
carrier, and rerun the test. If the test still fails, go to 
Step 5.
5. The active tone/clock may be faulty and incorrectly 
reporting the level of the ringing voltage. Replace 
the active tone/clock and rerun the test. Refer to 
TONE-BD Maintenance documentation for details on 
replacing the active tone/clock circuit pack. Rerun 
the test. If the test still fails, escalate the problem.
Table 10-373. TEST #118 Analog Ring Generator Query Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page