User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1203RING-GEN (Analog Ring Generator) 
10
Table 10-373. TEST #118 Analog Ring Generator Query Test 
Error 
Code
Test 
Result Description/ Recommendation
1
1000 
1001 
1003 
1115 
2012 
2100
ABORT Could not seize the resources to run the test. Other 
maintenance is running on the active tone/clock circuit 
pack.
1. Wait for the green LED on the active tone/clock 
circuit pack to go out; (use the status port-network 
command to determine the Active tone/clock circuit 
pack). 
2. Rerun the test. If the test aborts again, refer to 
TDM-CLK (TDM Bus Clock) Maintenance 
documentation.
2000 ABORT Response to the request was not received within the 
allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve all 
other tone/clock problems first.
2. Rerun the test.
1005 ABORT The tone/clock is unable to read the analog ringing 
voltage level when the tone/clock is in the Processor 
Interface slot. This test is not available for the Processor 
Port Network in this configuration.
Continued on next page