LED Interpretation 
Page 7-2Processor and Maintenance Circuit Pack LEDs 
7
NOTE:
Alarms on the PROCR, PR-MAINT, MEMORY, and PR-MEM MOs are 
indicated by the red LED on the Processor circuit pack.
■ Green (test)—the system is running tests on this circuit pack.
NOTE:
On the Standby Processor circuit pack, green means that the 
Standby Switch Processing Element (SPE) is not refreshed (that is, it 
is in Maintenance or Down Mode).
NOTE:
On the Maintenance circuit pack, the green LED may blink very 
faintly once per second. This is the normal operating state of the 
Maintenance circuit pack. The faint blink is due to a 
once-per-second self-test executed by the Maintenance circuit 
pack.
■ Yellow (busy)—this circuit pack is in use. In a high or critical reliability 
system, the yellow LED is always off for the Standby Processor and 
Memory circuit packs even when in Maint mode.
■ MAJOR ALARMS (red)
■ MINOR ALARMS (red)
■ WRNG (warning) ALARMS (yellow)
■ ACK (acknowledgment) (green)—indicates Major or Minor alarms have 
been reported to INADS
■ EMERGENCY TRANSFER (red)—indicates emergency transfer has been 
invoked
NOTE:
If the AC power cord is unplugged from the control cabinet, the 
emergency transfer feature invokes, however the EMERGENCY 
TRANSFER LED (red) is not lit due to loss of AC power.