User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1177PRI-CDR/SEC-CDR (PRI-CDR Link) 
10
Error Log Entries and Test to Clear Values
Notes:
a. System Technician has busied out the CDR link to out-of-service state. 
The CDR link is torn down.
b. Link Retry Test (#215) fails. The Aux Data field contains either the Channel 
ID of Data Channels on the TN777 circuit pack (that is, 3 for Channel 01, 4 
for Channel 02, 5 for Channel 03, 6 for Channel 04, and 9 for EIA port) or 
an Error Code of 99 indicating that no data channels are available for 
setting up the link, or an Error Type of 255 indicating an internal system 
error. Refer to the preceding ‘‘
Procedures for Restoring the CDR Link’’ for 
resolution.
c. The CDR physical link is down due to the following causes: cable to the 
CDR output device is disconnected; CDR output device is powered off, 
the data extension where the CDR output device connects to has been 
busied out or there is a scheduled daily interchange. The Aux Data field 
contains the Channel ID of Data Channels on the TN777 circuit pack (that 
is, 3 for Channel 01, 4 for Channel 02, 5 for Channel 03, 6 for Channel 04, 
and 9 for EIA port). Check the connectivity of wire and cable among wall 
jacket, data module, and the CDR output device. Enter status data 
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the 
set options command.
Table 10-357. CDR Link Maintenance Error Log Entries
Error 
Type
Aux 
Data Associated Test Alarm Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test cdr-link 
primary|secondary sh
18 (a) 0 busy out cdr WARNING OFF release cdr-link 
primary|secondary
primary|secondary
25 (b) 0
3 to 6
9
99
255
Link Retry Test (#215) MINOR/ 
WARNING
2
OFF test cdr-link 
primary|secondary l
513 (c) 0
3 to 6
9
test cdr-link 
primary|secondary
1025 (d)
1281 (e)