Page 10-1164PR-MAINT (Maintenance Processor) 
10
Table 10-350. TEST #229 MTP Auxiliary Loop Around Test 
Error 
Code
Test 
Result Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
1000 ABORT The system software resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018 ABORT The test has been disabled via administration. The change 
system-parameters cdr command needs to administer CDR.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2033 
2034
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
22902
22903
ABORT The system software resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Auxiliary channel failed the Loop Back Test. The AUX port is probably not 
sending any auxiliary data to the auxiliary collection device.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
PASS The Auxiliary channel passed the Loop Back Test. The auxiliary port is 
functioning correctly.
1. If no auxiliary data is being recorded, check the auxiliary collection 
device, and verify that it has been set up and connected correctly.
Continued on next page