User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1162PR-MAINT (Maintenance Processor) 
10
NOTE:
A dial-up (through the INADS port) does not display the results discussed 
in the previous paragraph. However, a dial-up through data channels does 
display these results.
Table 10-348. TEST #104 MTP Dual Port Ram Test 
Error 
Code
Test 
Result Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT (Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.)
1000 ABORT System software resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1030 ABORT The component on which the test was to be run is on the Standby SPE. This 
test may be run on this component only when it resides on the Active SPE.
1. For a recommended maintenance procedure, refer to ABORT Error 
Code 1030 in STBY-SPE Maintenance documentation.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2028 ABORT System software resources required for this test are not available.
2029 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The dual port RAM is not functioning correctly. Communication between 
the processor and MTP is lost. The system is not able to report 
environmental alarms, communicate with the Standby SPE, or reboot from 
tape, if necessary.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit pack.
PASS Dual port RAM is functioning. Communication exists between the 
80286/386 Processor circuit pack and the MTP.
Continued on next page