User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1133POWER (Battery & Battery Charger) for AC-Powered Systems 
10
10 FAIL This indicates that Error Codes 2 and 8 have occurred. 
Refer to these descriptions. Also, refer to the description 
for Error Code 14 for this test.
12 FAIL This indicates that Error Codes 4 and 8 have occurred. 
Refer to these descriptions. Also, refer to the description 
for Error Code 14 for this test.
14 FAIL This indicates that Error Codes 2, 4, and 8 have 
occurred. Refer to these descriptions.
NOTE:
This could also indicate that the detection logic on 
the DUPINT (Duplication Interface), PR-MAINT 
(Maintenance/Tape Processor), or EPN MAINT 
(Maintenance) circuit pack is defective. Such an 
error will not be detected by the respective 
maintenance. If many environment tests are 
failing, replace the suspect circuit pack 
(depending on system configuration).
PASS The Maintenance/Tape Processor in a multicarrier 
cabinet PPN system without High or Critical Reliability, 
the Duplication Interface circuit pack in a PPN for a High 
or Critical Reliability system, or the EPN Maintenance 
circuit pack in an EPN have reported that the status of 
Battery & Battery Charger is good.
Table 10-332. TEST #5 Battery & Battery Charger Query Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page