User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1129POWER (Battery & Battery Charger) for AC-Powered Systems 
10
4 FAIL The battery is currently being charged at the high 
charge rate.
1. After 30 hours, the battery should be fully charged, 
and this error should disappear.
2. If after 30 hours the battery is still in the high charge 
rate, an alarm is raised. Display the Error Log with 
the display errors command and select the 
category "environ" to display only 
environment-related errors. Look for POWER errors 
of type 257. The FIRST OCCURRENCE of this error 
indicates the time when the battery started charging. 
Use this time as the starting point to determine if the 
battery has been charging for 30 hours. If the battery 
has been charging for 30 hours, then replace the 
battery.
!
CAUTION:
Read the section, ‘‘Replacing the Battery and 
Battery Charger’’ before proceeding.
Table 10-332. TEST #5 Battery & Battery Charger Query Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page