User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1097PKT-CTRL (Packet Control Circuit Pack) 
10
Table 10-323. TEST #583 Packet Control Error Counter Read/Clear Test 
Error 
Code
Test 
Result Description/ Recommendation
1029 
2011 
2012 
2013 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1141 FAIL The Packet Control circuit pack is not operational. A busied-out Packet 
Control circuit pack can still be operational.
1. Determine if the Packet Control circuit pack has an active major alarm 
(via the display alarm command). If it does, follow the recommended 
repair procedures to retire the alarm. Once the alarm is retired, the 
original command can be retried.
2. If the Packet Control circuit pack does not have an active major alarm, 
wait one minute and retry the original command. If the Error Code 
1141 is again observed, go to the next step.
3. If the Packet Control circuit pack is on the active SPE and is not 
currently busied-out, issue the busyout packet-control C command. 
Issue the reset packet-control C command. If the reset command 
fails, follow the recommended repair procedures for Test #586. If the 
reset command passes, issue the release packet-control C 
command (if the Packet Control circuit pack is on the active SPE), and 
reissue the original command. 
Continued on next page