Maintenance Object Repair Procedures 
Page 10-1084PKT-BUS (Packet Bus) 
10
Notes:
a. Within the last minute, packet circuit packs have reported errors that 
indicate a possible Packet Bus failure. The Aux Data value is 1 or 2, 
indicating that only one or more than one Packet circuit pack 
(respectively) have reported a possible Packet Bus failure.
b. Packet Bus maintenance has been unable to perform loop around tests 
from the TN778 Packet Control circuit pack (PKT-CTRL) to itself. This 
could indicate faults on the Packet Control circuit pack rather than on the 
Packet Bus. Examine the Error and Alarm Logs for any such errors.
c. The Maintenance/Test Packet Bus port for this port network has 
determined that there are more Packet Bus faults than the port can 
correct. The Aux Data value indicates the number of faulty leads.
d. Packet circuit packs have detected possible Packet Bus failures via in-line 
error or background test failure. Examine the Error and Alarm logs for 
more specific PKT-BUS errors.
e. The Maintenance/Test Packet Bus port has caused Packet Bus leads to 
be swapped to spare leads. This error appears only in a High or Critical 
Reliability system. The Aux Data value indicates the number of faulty 
leads. If this is the only active error against the Packet Bus, the Packet 
Bus is still in service. Therefore, due to the disruptive nature of the 
Packet Bus Fault Isolation and Correction procedures, repairs should be 
deferred until a time when these procedures cause the least interruption in 
service. This matter is resolved via consultation with the customer. 
However, be sure not to delay repairs for too long, since the switch is not 
able to recover from another Packet Bus failure until the existing one is 
resolved. The procedure described in the section entitled "Special 
Precaution Concerning the TN771" in Chapter 9, ‘‘
Packet Bus Fault 
Isolation and Correction’’ is used to ensure that the Maintenance/Test is 
giving correct information. This procedure may require that a new TN771 
be taken to the customer site.
f. The Maintenance/Test Packet Bus port has detected open leads on the 
Packet Bus. The Aux Data value indicates the number of open leads.
g. Packet circuit pack, port, and endpoint maintenance has been disabled 
due to a Packet Bus failure. The Aux Data value indicates which sources 
have reported errors that have caused maintenance to be disabled. These 
sources include the following:
■ In-line errors from Packet circuit packs.
■ Packet Bus Uncorrectable report from the Maintenance/Test Packet 
Bus port.
■ Packet Bus Interface Failure report from the Packet Control.
■ In an EPN, packet circuit pack, port, and endpoint maintenance will 
be disabled if a Packet Bus failure occurs in the PPN.