User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1054PI-LINK (Processor Interface Link) 
10
Error Log Entries and Test to Clear Values
Table 10-304. PI-LINK (Processor Interface Link) Error Log Entries 
Error 
Code
Aux 
Data Associated Test Alarm Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test link <lnk-no> sh
1 (a) Any none MAJOR/ 
WARNING
2
OFF busyout/release link 
lnk-no
18 0 busyout link lnk-no WARNING OFF release link lnk-no
257 (b) Any none MINOR/ 
WARNING
2
OFF busyout/release link 
lnk-no
263 (c) Any none MAJOR/ 
WARNING
2
OFF busyout/release link 
lnk-no
513 (d) Any none MAJOR/ 
WARNING
2
OFF busyout/release link 
lnk-no
769 Any PI Loop Around Test 
(#182)
WARNING ON test link lnk-no l r 2
1025 Any TDM Loop Around 
Test (#183)
WARNING OFF test link lnk-no l r 2
1281 (n) Any none WARNING/ 
MAJOR
3
OFF test link lnk-no sh r 2
1537 (e) Any none WARNING/ 
MAJOR
3
OFF busyout/release link 
lnk-no
1793 (f) Any none WARNING OFF busyout/release link link 
no.
2049 (g) Any none WARNING/ 
MAJOR
3
OFF test link lnk-no sh r 9
2305 (h) Any none WARNING OFF test link lnk-no sh r 9
2561 (i) Any none WARNING OFF busyout/release link 
lnk-no
2817 (j) Any none NONE OFF busyout/release link 
lnk-no
3073 (k) Any none WARNING OFF test link lnk-no sh r 9
Continued on next page