User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1033PE-BCHL (PRI Endpoint Port) 
10
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates a disagreement between the switch and the 
terminal adapter at the other end of the connection with regard to the 
ISDN 
call
 state of the PRI Endpoint Port. This switch automatically tries to 
recover by clearing the call (that is, the call is torn down). The status 
pri-endpoint <extension> command can be used to determine the state 
of the port.
When running the Short Test Sequence of tests, pay close attention to the 
results of the Call State Audit Test (#257).
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-294. PRI Endpoint Port Error Log Entries 
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any None test port PCSSpp sh r 1
15 (b) Any Audit and Update 
Test (#36)
18 (c) 0 busyout pri-endpoint 
<extension> busyout 
port <PCSSpp>
WARNING OFF release pri-endpoint 
<extension> release port 
<PCSSpp>
129 (d) None WARNING OFF test port PCSSpp sh r 1
130 (e) None WARNING ON test port PCSSpp sh
257 (f) Any None test port PCSSpp sh r 1
513 (g) Any None WARNING OFF test port PCSSpp sh r 1
76 9 (f) Any None test port PCSSpp sh r 1
1281 (h) Any Conference Circuit 
Test (#7)
MINOR ON test port PCSSpp l r 4
1537 (i) Any NPE Crosstalk Test 
(#6)
MINOR ON test port PCSSpp l r 3
1793 (j) Any None test port PCSSpp sh r 1
3073 (k) Any Service State Audit 
(#256)
test port PCSSpp sh r 2
3585 (l) Any None None
Continued on next page