Maintenance Object Repair Procedures 
Page 10-1014PDMODULE, TDMODULE (Data Module) 
10
2001 ABORT System resources required to run this test are not 
available.
1. Retry the test at one-minute intervals a maximum of 
five times.
2. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to 
run this test.
1. Rerun the test at one-minute intervals a maximum of 
five times.
2. If the test continues to abort, escalate the problem.
2500 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to fail, escalate the problem.
15 FAIL The control channel between the processor and Digital 
Line circuit pack is not transmitting properly. This can 
cause a wide range of effects. The user may notice 
nothing or the port may be totally unusable. This could 
also disrupt other users.
1. Run circuit pack tests to check the Tone Generator 
and the Tone Detector circuit packs using the test 
board UUCSS short command.
2. Resolve any problems that are detected on the Tone 
Generator circuit pack or Tone Detector circuit 
pack.
3. If the Tone Generator and Tone Detector circuit 
packs are functioning properly, and the test still 
fails, replace the Digital Line circuit pack.
Table 10-290. TEST #13 Information and Control Channel 
Local Loop Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page