Maintenance Object Repair Procedures 
Page 10-1004PDMODULE, TDMODULE (Data Module) 
10
Hardware Error Log Entries and Test to Clear 
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2. G3iV1.1-286 and G3iV2-386 only.
PDMODULE and TDMODULE Error Log Entries
Error 
Type
Aux 
Data Associated Test Alarm Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None WARNING OFF
1 (b) 1 to 20 None WARNING OFF
15 (c) Any None
18 (d) 0 busyout port 
PCSSpp
WARNING OFF release port PCSSpp
257 (e) 40971 None
513
2
0 Data Module Audits 
Test (#17)
WARNING 
(j)
OFF test port PCSSpp sh r 6
769 (f) 40988 None WARNING OFF
1281 Any Data Module Audits 
Test (#17)
WARNING OFF test port PCSSpp sh r 4
1537 (g) 40968 None WARNING OFF
1793 Information 
Channel and 
Control Channel 
Loop Around Test 
(#13)
MINOR ON test port PCSSpp l r 3
2049 NPE Crosstalk Test 
(#9)
MINOR ON test port PCSSpp l r 3
2305 (h) 32770 None
2305 (i) 40967 None
2561 Data Module 
Internal Loop 
Around Test (#175)
WARNING OFF test port PCSSpp l r 5
2817 (k) Link GPP Loop 
(183) Against Links
MAJOR ON
3841 (l) NONE