User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-999OPS-LINE (DS1 OPS Line) 
10
2000 ABORT The test was aborted because response to the test was 
not received within the allowable time period.
1. Retry the command at 1-minute intervals for a 
maximum of 5 times.
2. If the test aborts with error code 2000 again, run 
short test sequence on the associated DS1-BD or 
UDS1-BD. If tests 138 through 145 on the 
associated DS1-BD or UDS1-BD are also aborting 
with error code 2000, hyperactivity on the board or 
facility is indicated. In this case, the hyperactivity 
problem should be dealt with first.
3. If the test continues to abort and the board is OK, 
escalate the problem.
2012 ABORT The test was aborted due to a system error.
2100 ABORT Could not allocate the necessary system resources to 
run this test.
1. Retry the command at 1-minute intervals for a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1 FAIL Internal System Error.
1. Look for DS1-BD errors in the Hardware Error Log. If 
present, refer to the DS1-BD (DS1 Interface Circuit 
Pack) Maintenance documentation.
2. If a channel multiplexer is used as the remote DS1 
endpoint to which the station connects, refer to the 
multiplexer vendor’s maintenance document for 
diagnosis.
3. Retry the command at one-minute intervals a 
maximum of five times.
4. If the test continues to fail, escalate the problem.
PASS The station hook states in both switch software and DS1 
Interface circuit pack are consistent.
Table 10-288. TEST #312 DS1OPS Switchhook Inquiry Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page