User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-996OPS-LINE (DS1 OPS Line) 
10
2000 ABORT The test was aborted because response to the test was 
not received within the allowable time period.
1. Retry the command at 1-minute intervals for a 
maximum of 5 times.
2. If the test aborts with error code 2000 again, run 
short test sequence on the associated DS1-BD or 
UDS1-BD. If tests 138 through 145 on the 
associated DS1-BD or UDS1-BD are also aborting 
with error code 2000, hyperactivity on the board or 
facility is indicated. In this case, the hyperactivity 
problem should be dealt with first.
3. If the test continues to abort, escalate the problem.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
7 or 8 FAIL Test failed due to internal system error. Do not replace 
port board.
■ Error code 7: the failure occurred during station 
translation download (to DS1 Interface circuit pack).
■ Error code 8: the failure occurred during station 
ringer update.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to fail, escalate the problem.
PASS Trunk translation has been updated successfully. The 
current trunk states kept in the DS1 Interface circuit 
pack and switch software are consistent.
Table 10-287. TEST #36 Audit and Update Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page